How to ensure healthy air at home? Part 2
Part one: Humidity and humidity sensors
Part two: Carbon dioxide and СО2 sensors
Another important air quality parameter is the volume fraction of carbon dioxide (СО2), the main source of which is people generating it through breathing. In a poorly ventilated room with people present, this parameter is gradually increasing together with humidity. Therefore, the more people are present in the room, the faster the concentration of this harmful gas will increase. Consequently, it is very important to monitor CO2 concentration in the air and to organize such air exchange that would ensure a comfortable level of its content.
The most comfortable air for a person is considered outdoor air containing approximately 0.04 % of carbon dioxide or 400 ppm (parts per million). In a room with people, CO2 content rise is inevitable, while its increase to 0.08 % (800 ppm) does not affect a person’s wellbeing in any way and such air can be considered normal. When CO2 concentration reaches range of 0.08–0.10 % (800–1000 ppm), such air quality is now considered mediocre. With such CO2 concentration in the air, some people may feel slight general discomfort. When CO2 concentration reaches the range of 0.10–0.14 % (1000–1400 ppm), a person may start feeling fatigue, experience laboured breathing, problems with the nasopharynx, as well as troubles with maintaining attentiveness and information processing. In most countries, such CO2 content is considered as the lower limit of acceptable norm. When carbon dioxide content reaches over 0.14 % (1400 ppm), air quality is considered low. In such environment, a person can experience severe fatigue and lethargy, lack of initiative and apathy, problems with concentration and sleep. When CO2 content reaches over 0.2 % (2000 ppm), human body reacts to it even in a more pronounced manner: headaches and other ailments appear, a person experiences reluctance to work and engage in mental activity, may suffer from chronic diseases of the nasopharynx, etc. Prolonged stay in a room with carbon dioxide content within the range of 0.25–0.5 % (2500–5000 ppm) may lead to serious health problems. As a result of constant impact of high CO2 concentration, an increase in blood acidity occurs, which can lead to acidosis – a shift in the acid-base balance of the body towards an increase in acidity. Acidosis can provoke such diseases as diabetes, problems with the musculoskeletal and cardiovascular systems, general weakness.
There is a widespread belief that airing of the room is performed with the purpose of replenishing the supply of oxygen, which is gradually decreasing due to its constant human consumption. This is partially true, but more important result of airing is the removal of excess carbon dioxide from the room. It is known that in order to be comfortable for humans, the air should contain 20.9 % oxygen. At the same time, oxygen content decrease to 15 % or an increase to 80 % does not significantly affect the human body. The same cannot be said for the carbon dioxide because even a small change in its concentration by 0.1 % has a noticeable negative effect on a person. That is why controlling carbon dioxide concentration in the air is very important, especially in pre-school facilities and in schools. It is no secret that many schools are still not equipped with forced ventilation systems and airing is done by simply opening windows. Controlling of СО2 levels allows identifying increased carbon dioxide concentration and ensuring better ventilation within the facility, and therefore improving students wellbeing and mental functions, as well as their perception of information taught.
SOLUTION. A special carbon dioxide sensor allows identifying СО2 concentration within a room. This device is useful in residential, office and commercial premises with large crowds of people, such as in classrooms, conference-halls, etc. Such sensors may operate as both standalone devices and as integrated parts of ventilation equipment. In the latter case, it allows ventilation equipment to automatically turn on and off and to change its operation mode depending on carbon dioxide concentration within the room. There are sensor modifications equipped with a mode switch and LED lights for CO2 concentration, which allows activating the ventilation only when it is necessary, i.e. when the indicator is triggered.
The VENTS CO2 sensor is designed for indoor carbon dioxide concentration measurement and air capacity control of ventilation equipment based on CO2 concentration. The sensor has two separate outputs: a normally opened dry relay contact and an analogue output–10 V. The relay output is used to turn the ventilation equipment on/off depending on indoor CO2 concentration and the analogue output is used for smooth fan speed control for a fan with EC motor or a fan with extra speed controller with 0–10 V input. In case of smooth fan speed control the fan speed varies proportionally to carbon dioxide emissions. The relay and analogue outputs make the sensor compatible with any ventilation system. The integrated self-calibration system ensures reliable sensor operation during the sensor service life.
The sensor is available in two modifications: VENTS CO2-1 and VENTS CO2-2. The CO2-1 model incorporates built-in LED lights for CO2 concentration and an operation button. Three modes are provided: on, off, operation by CO2 concentration. The button is used to switch the ventilation equipment on or off when CO2– based ventilation control is not required. The CO2-2 model has no LED-lights and on/off button. This model is applied for premises requiring permanent ventilation, i.e. at school classes and other public premises.
Self-calibrating sensor DPWQ40200 with microprocessor control for measuring carbon dioxide content in the air within the range from 0 to 2,000 million-1 (parts per million). The sensor has 2 analogue outputs (0–10 V and 4–20 mA), which allow stepless fan speed control. With stepless control the fan speed is changed in proportion to carbon dioxide concentration changes. The CO2 content in the air is measured by means of a non-dispersive infrared analyser (NDIR).
To be continued…
Read more
25 Nov 2024
High-quality ventilation for school shelters
21 Aug 2024
Products by VENTS for kitchens and bakeries
14 Aug 2024
Noise of a domestic fan: how to evaluate it?
23 Jul 2024
Vents contributed to a charity project
19 Jun 2024
Air pollution: what do we breathe in?
30 Apr 2024
Vents took part in thermal modernization of another Kyiv kindergarten
16 Apr 2024
Vents was awarded the UA Epicentr Awards
20 Dec 2023
Decentralised VENTS units: SMART, ECONOMICAL, STYLISH
12 Dec 2023
VENTS provided ventilation for the new “Dacha” family house for cancer-affected children
5 Dec 2023
Vents is ranked among the most successful companies in Ukraine by Forbes Ukraine
23 Nov 2023
New VENTS equipment: ENERGY SAVING, MODERN DESIGN, SMART TECHNOLOGY
8 May 2023
Vents fans were selected for organising ventilation in a new residential complex
9 Mar 2023
Airing the room without heat losses
7 Dec 2021
Vents has provided the air-conditioning equipment to Ukraine’s largest shopping and entertainment center
10 Nov 2021
Yulia Dvorakovskaia: “We chose Vents equipment for the new innovative clinic”
8 Jul 2021
World-class ventilation
26 May 2021
Scientists recognize the leading role of ventilation in the fight against the spread of COVID-19
29 Apr 2021
How to ensure healthy air at home? Part 3
10 Feb 2021
Ventilation of the Georgian clinic is provided by VENTS equipment
24 Nov 2020
How to ensure healthy air at home? Part 1
16 Nov 2020
Vents ventilation solutions around the world
3 Jun 2020
Clean air safeguards against virus diseases
6 May 2020
Ventilation in mobile hospitals: international experience and ventilation solutions
25 Jun 2019
Expanded polypropylene: the benefits of a high-tech material
19 Oct 2015
KAM fireplace fan: efficient heating control for your home
6 Aug 2014
Antibacterial Coating of VENTS Ventilation Products: Say ‘No’ to Germs!
26 Jun 2014
VENTS – A social stability guaranty
27 Mar 2014
Hydroponics ventilation basics
14 Mar 2011
Regulated air exchange and energy saving
23 Feb 2011
HARDI and ASHRAE magazines about VENTS products
20 May 2010
Ukrainian manufacturer with international name
23 Feb 2010
Advantages of the Ventilation
28 Nov 2008
“VENTS”’s Collection of Awards Replenished by New Order
22 Sep 2008
A solemn ceremony of awarding winners of “The Best Entrepreneur of the Year – 2008”
30 May 2008
“Records For The Sake of Life”
7 Feb 2008
JSC Ventilation Systems is the Leader of the Branch 2007
18 Sep 2007
Choice of the Year – 2007
5 Mar 2007
VENTS – fashion maker in ventilation
7 Feb 2007
“Race under Chestnuts”
5 Feb 2007
A new website for the American customers